CCS LED光源 PSB3-30024 Series 控制器 (定電壓)
Light controllerIt operates on a 100 to 240 VAC input and measures 97 x 245 x 110 mm (width x depth x height).
-
Model
PSB3-30024
Lighting Method
Continuous lighting
Drive Method
Constant-voltage system
Intensity control method
Variable voltage control
No. of channels
1 channel
Applicable Light Unit (rated)
24 V 300 W
Intensity
control
Manual and external intensity
Manual/External switch (MODE)
control
Variable output voltage range
Select between 3 steps by using the intensity range selector (RANGE).
Manual
Set any of 256 steps via the setting switch. Press and hold the switch for 2 seconds to lock the intensity value.
External
Parallel
communication
8-bit intensity value setting (B0 to B7) and write signal (WR)
Serial
communication
Command input via EIA-485 communication
Analog input
Analog voltage (0 V to +5 V)
External control mode can be selected by pushing the setting switch while turning ON the power.
ON/OFF control
Parallel bit input
Lighting signal (OFF)
ON/OFF control
Serial
communication
Command input via EIA-485 communication
EIA-485 communication settings
ID
Set by using the ID switch (00 to 03) Connect up to four units
EIA-485 communication settings
Terminating
resistance
Set by using the ID switch
(Terminating resistance is ON only when ID = 00)
Lighting delay (typ.)
0.1 s
Error detection display
"Err" is displayed on the digital display.
Error detection output
Errors are output and light output is stopped for an internal AC power error.
Error detection output
External control Connector
Error output terminal (OC, OE), photocoupler insulation, open-collector output, alert open (load current of 10 mA or less), and error status (serial communication)
Over current protection
Operates at 105% of the rated current or higher. Resets by cycling the Control Unit.
Overvoltage protection
Operates at 120% to 155% of the rated voltage. Resets by cycling the Control Unit.
Input voltage (rated)
100 to 240 VAC (±10% - 15%), 50/60 Hz
Power consumption (typ.)
410 VA
Frequency
50/60 Hz
Inrush current (typ.)
40 A at cold start
Ground leakage current
3.5 mA max. (264 VAC, 60 Hz, with no load)
Output voltage variation range (typ.)
Select between 3 steps by using the intensity range selector.
12 V to 24 V *With no load
15 V to 24 V *With no load
18 V to 24 V *With no load
Operating temperature and humidity
Temperature: 0 to 40°C, Humidity: 20% to 85%RH (with no condensation)
Storage temperature and humidity
Temperature: -20 to 60°C, Humidity: 20% to 85%RH (with no condensation)
Vibration resistance
Acceleration: 19.6 m/sec2, Frequency: 10 to 55 Hz, Cycle: 3 min., Sweep cycle: each hour in the X, Y, and Z directions
Cooling method
Forced air cooling
CE marking
Safety standard: EN61010-1 compliant, EMC standard: EN61326-1 Class A compliant
Environmental
regulations
RoHS compliant
Material, coating, surface processing
Steel plate, Thickness of cover: 1.0, Thickness of chassis: 1.6, N3 leather tone finish
Weight
2,300 g max.
Accessories